Open cell or closed cell spray foam: which one for the job

Closed cell (Thermoseal HFO, R-7.4 per inch, 2 lb density) where you need strength, a vapor retarder or a high R-value in a thin cavity: crawlspaces, rim joists, metal buildings, below grade. Open cell (Thermoseal 500, R-4.1 per inch, 0.5 lb) where there is depth to fill and sound matters: attic roof decks, interior walls, between floors.

2 min read · Updated October 26, 2026

Both foams insulate and air-seal. The difference is density, and density decides everything else: R-value per inch, how much water vapor gets through, how strong the cured foam is, and how far a set goes.

The numbers side by side

PropertyThermoseal HFO (closed cell)Thermoseal 500 (open cell)Thermoseal 800 (open cell)
Core density1.9 to 2.1 lb/ft³0.5 lb/ft³0.75 lb/ft³
R-value per inch (ASTM C518)7.4 (R-25 at 3.5 in)4.14.5
Cell structureover 92 percent closedover 97 percent openopen
Water vapor permeance (ASTM E96)0.86 perms at 1.37 in6.15 perms at 3.5 insee data sheet
Air-impermeable at (ASTM E283 / E2178)2.0 in3.5 insee data sheet
Compressive strength (ASTM D1621)27.4 psinot rated for loadnot rated for load
Sound (STC, ASTM E413)not the strengthSTC 39see data sheet
Blowing agentHFO, GWP of 1waterwater
Surface burning (ASTM E84)Class 1, flame spread 10, smoke under 450Class 1, flame spread under 25, smoke under 450Class 1

Where closed cell goes

  • Crawlspace walls and band joists. It wants a vapor retarder, it may get wet, and 2 inches gives an air barrier and R-15 in one pass of work.
  • Rim and band joists anywhere. Thin cavity, high R, stops the air that batts never did.
  • Metal buildings and pole barns. Bonds to the skin, stops condensation on the inside of the metal, adds stiffness.
  • Below grade and basement walls. Water resistance and the vapor retarder in one product.
  • Exterior walls in cold climates where the assembly needs the vapor retarder on the warm side.
  • Roofing and anywhere strength matters. Thermoseal HFO passes wind uplift at 210 psf and the Fortified roof test on its data sheet.
  • Flash and fill. Two inches of closed cell for the air and vapor control, then open cell or batt to fill the cavity at a lower cost per inch.

Where open cell goes

  • Attic roof decks. Depth is there (5.5 to 10 inches in a rafter bay), the vapor retarder is usually not wanted on the roof deck, and the softer foam is forgiving over sheathing seams.
  • Interior walls, between floors, media rooms. STC 39 and a noise reduction coefficient of 0.75 on the Thermoseal 500 sheet.
  • Any deep cavity in a mild or hot climate where the assembly does not call for a vapor retarder.
  • Big, irregular spaces where yield matters more than inches: an open-cell set covers roughly three and a half times the board feet of a closed-cell set.

The two questions that decide it

  1. Does the assembly need a vapor retarder on this side? Cold climate, warm side of the wall, crawlspace, basement: closed cell. Roof deck in a vented-to-unvented attic conversion, interior partitions: open cell.
  2. How much depth is there? Under 3 inches of cavity and an R-value to meet: closed cell. Six inches or more and a budget: open cell.

Strength, water, thin cavities and code vapor retarders go to closed cell. Depth, sound and cost per cavity go to open cell. Most houses get both.

Both need a barrier over them

Spray foam inside a building needs a thermal barrier (usually half-inch drywall) or, in attics and crawlspaces that are only entered for service, an ignition barrier or a listed coating. The ignition and thermal barrier guide has the coating rates from the Thermoseal evaluation reports.

Quick answers

What is the R-value of closed-cell spray foam per inch?
Thermoseal HFO is R-7.4 per inch and R-25 at 3.5 inches (ASTM C518).
What is the R-value of open-cell spray foam per inch?
Thermoseal 500 is R-4.1 per inch; Thermoseal 800, the 0.75 lb open cell, is R-4.5 per inch (ASTM C518).
Is closed-cell spray foam a vapor barrier?
Thermoseal HFO measures 0.86 perms at 1.37 inches, which puts it under 1 perm, the usual line for a vapor retarder. Open cell at 3.5 inches is 6.15 perms and is not a vapor retarder.
At what thickness is spray foam an air barrier?
Thermoseal HFO closed cell is air-impermeable at 2 inches and Thermoseal 500 open cell at 3.5 inches, by the ASTM E283 and E2178 tests on the data sheets.

Sources